The Causes of Corrosion of Main Oil Pumping Units Causes Them to Catch Fire

Issue 3(89) 2018
Pages 43-50

M.A. Belokurova, Moscow Polytechnic University (MAMI), Moscow, Russian Federation

I.I. Reformatskaya, Academy of the State Fire Service EMERCOM of Russia, Moscow, Russian Federation

A.A. Schevchenko, MAMI, Moscow, Russian Federation


Keywords: corrosion, oil-trunk pumping to aggregates, motor oil

http://www.doi.org/10.31615/j.corros.prot.2018.89.3-5 

 

The causes of early failure of the node of angular contact bearings and the occurrence of oil leakage from main oil pump in to aggregates are analyzed. It is shown that corrosion damage of the bearing unit is one of the reasons of fire risk in the enterprise. The measures of corrosion protection were proposed.